dc.description.abstractThe impact of the inclusion of a vapour check membrane in timber buildings on indoor air quality, measured as volatile organic compounds (VOCs), was determined by Photo Ionization Detection. Two identical buildings were constructed except one building (test) contained an Intello vapour check membrane and the other building was the control. A VOC source (Wattyl Estapol High Performance Interior Clear Polyurethane Satin varnish) was placed in each building and the subsequent concentrations were monitored until background levels were resumed. Data analysis demonstrated that the VOC levels in the test house were consistently higher than those established in the control house (student t-test > 99.9% confidence). Average concentrations for VOC, temperature and relative humidity respectively were 3.23 ppm (control), 6.54 ppm (test); 17.3°C (control), 17.4°C (test) and 52.4% (control) and 54.7% (test). The humidity was also significantly higher in the test house (student t-test >99.9% confidence). Originally temperature differences were not found to be statistically conclusive; however this appeared to have been because the diurnal pattern of the temperature profile masked the difference in temperature. By removing this diurnal pattern, the temperatures in the houses were found to be significantly different over a 7 day timescale (student t-test >99.9% confidence). Diurnally, there was a strong link between VOC concentration and temperature and an inverse relationship with relative humidity. The use of the vapour control membrane had a significant effect on the indoor air quality of the buildings (based on the concentration of VOCs) which may have been due to: (1) the increased temperature and humidity, (2) the change in air flow from outside the buildings or (3) a combination of all three factors. There is a strong link between VOC concentration and temperature within the houses which may explain the highly variable profile of VOC concentration with time. An inverse relationship was observed with relative humidity.en_NZ
dc.language.isoenen_NZ
dc.publisherInternational Proceedings of Chemical, Biological and Environmental Engineeringen_NZ
dc.relation.urihttp://www.ipcbee.com/vol90/rp016_ICECB2015-L3009.pdfen_NZ
dc.rightsCopyright ©2008-2015. International Proceedings of Chemical, Biological and Environmental Engineering.en_NZ
dc.subjectindoor air qualityen_NZ
dc.subjectvolatile organic compounds (VOC)en_NZ
dc.subjectvapour checken_NZ
dc.subjectvapour control membranesen_NZ
dc.subjectweathertightnessen_NZ
dc.subjectbuilding technologyen_NZ
dc.titleThe effect of vapour-control membrane technology on indoor air quality in buildingsen_NZ
dc.typeConference Contribution - Paper in Published Proceedingsen_NZ
dc.rights.holderInternational Proceedings of Chemical, Biological and Environmental Engineeringen_NZ
dc.identifier.doi10.7763/IPCBEEen_NZ
dc.subject.marsden120202 Building Science and Techniquesen_NZ
dc.identifier.bibliographicCitationBerry, T., & Chsiwell, J.H.D. (2015, November). The Effect of Vapour-Control Membrane Technology on Indoor Air Quality in Buildings In Liu Juan (Ed.), International Proceedings of Chemical, Biological and Environmental Engineering (pp.87-93). 90 (14). 10.7763/IPCBEE.en_NZ
unitec.institutionUnitec Institute of Technologyen_NZ
unitec.publication.spage87en_NZ
unitec.publication.lpage93en_NZ
unitec.publication.volume90 (14)en_NZ
unitec.publication.titleInternational Proceedings of Chemical, Biological and Environmental Engineeringen_NZ
unitec.conference.titleInternational Proceedings of Chemical, Biological and Environmental Engineering (IPCBEE 2015)en_NZ
unitec.conference.orgInternational Proceedings of Chemical, Biological and Environmental Engineeringen_NZ
unitec.conference.locationunknownen_NZ
unitec.conference.sdate2015-11
unitec.conference.edate2015-11
unitec.peerreviewedyesen_NZ
dc.contributor.affiliationUnitec Institute of Technologyen_NZ
unitec.identifier.roms58879en_NZ
unitec.institution.studyareaConstruction + Engineering