Show simple record

dc.contributor.authorBlut, Dominik Patricio Ferdinand
dc.date.accessioned2015-11-17T01:54:18Z
dc.date.available2015-11-17T01:54:18Z
dc.date.issued2015-06-17
dc.identifier.urihttps://hdl.handle.net/10652/3109
dc.description.abstractBACKGROUND: Low levels of salivary SIgA have been associated with upper respiratory tract infection, oral ulceration and systemic diseases. Osteopathic Manipulative Treatment has been shown to have a positive effect on salivary SIgA levels. OBJECTIVE: This single case study aimed to determine changes in salivary SIgA concentration and secretion rate in response to a single 7-minute intervention of the osteopathic thoracic lymphatic pump in four male subjects who indicated suppressed mucosal immunity identified by recurrent upper respiratory tract infection and oral ulceration. METHODS: On a single day a total of nine saliva samples were collected per participant via oral swab, including four samples pre-, one peri- and four post-intervention. Participant results were analysed individually with group statistics reported. RESULTS: At baseline all participants showed suppressed levels of salivary SIgA concentrations with an average of 58.03 μg/mL (<79.26 μg/mL). Post-intervention Salivary SIgA concentrations increased in three participants [Effect size (ES) = 1.74 - 2.71]. On average salivary SIgA concentrations increased to 72.73 μg/mL (25.3%). Salivary SIgA secretion rates showed no clear pattern of change (ES = -1.82 to 1.96). On average salivary SIgA secretion rates increased from 23.8 μg/min to 24.4 μg/min (5.9%). The mean effect size for salivary SIgA secretion rates baseline to post-intervention was d=0.05. CONCLUSION: This study showed some indication of an overall trend for an increase in salivary SIgA concentration. Changes in salivary SIgA secretion rate were inconsistent and the therapeutic benefit of the thoracic lymphatic pump in participants with a suppressed mucosal immune function remains unclear.en_NZ
dc.language.isoenen_NZ
dc.subjectantibodiesen_NZ
dc.subjectaphthous ulcersen_NZ
dc.subjectrecurrenten_NZ
dc.subjectbiomarkersen_NZ
dc.subjectmanual immunomodulatory therapyen_NZ
dc.subjectosteopathic medicineen_NZ
dc.subjectserologyen_NZ
dc.subjectimmune systemen_NZ
dc.subjectthoracic lymphatic pump techniqueen_NZ
dc.subjectlymphatic pump techniqueen_NZ
dc.subjectimmunoglobulin A levelsen_NZ
dc.titleThe effect of the osteopathic thoracic lymphatic pump technique on salivary secretory immunoglobulin A levels in adults with recurrent upper respiratory tract complaintsen_NZ
dc.typeMasters Thesisen_NZ
thesis.degree.nameMaster of Osteopathyen_NZ
thesis.degree.levelMastersen_NZ
thesis.degree.grantorUnitec Institute of Technologyen_NZ
dc.subject.marsden110499 Complementary and Alternative Medicine not elsewhere classifieden_NZ
dc.subject.marsden110203 Respiratory Diseasesen_NZ
dc.identifier.bibliographicCitationBlut, D. P. F. (2015). The effect of the osteopathic thoracic lymphatic pump technique on salivary secretory immunoglobulin A levels in adults with recurrent upper respiratory tract complaints. An unpublished research project submitted in partial fulfilment of the requirements for the degree of Master of Osteopathy, Unitec Institute of Technology.en_NZ
unitec.pages84en_NZ
unitec.institutionUnitec Institute of Technologyen_NZ
dc.contributor.affiliationUnitec Institute of Technologyen_NZ
unitec.advisor.principalBacon, Catherine
unitec.institution.studyareaOsteopathy


Files in this item

Thumbnail

This item appears in

Show simple record


© Unitec Institute of Technology, Private Bag 92025, Victoria Street West, Auckland 1142