Show simple record

dc.contributor.authorTaingahue, Matiu John
dc.date.accessioned2015-06-28T23:52:54Z
dc.date.available2015-06-28T23:52:54Z
dc.date.issued2015en_NZ
dc.identifier.urihttps://hdl.handle.net/10652/2886
dc.description.abstractBACKGROUND: Movement screening has become standard practice in a range of sports injury settings, however, few standardised protocols have undergone rigorous testing, and the biological variability in athletes’ performance has seldom been investigated or discussed in the movement screening literature. AIM: to investigate the intra-athlete within- and between-session variability of the Triple-Joint Flexion Test (TJFT) in adolescent, development-level, court and field sport athletes. DESIGN: video-based, repeated-measures. METHODS: Two-dimensional video rating and kinematic analyses were performed on simultaneous front and side views of 17 uninjured, male, adolescent athletes (mean ± SD age = 16.9 ± 0.9 years) performing 6 repetitions of the TJFT; and 14 athletes who repeated the TJFT 24h later. Two digital cameras (Panasonic HC-V520M) and video analysis software (PnO Data Solutions, CA, United States) were used to capture, synchronise and analyse the images. Intraclass correlation coefficients (ICC) and typical errors (TE) were used to assess within- and between-day reliability of all variables. Friedman’s and Wilcoxon signed-rank tests were used to check for systematic changes in rating score within- and between-sessions. RESULTS: The within-session reliability of rating scores (TE 1.5 to 0.7 pts, ICC 0.14 to 0.87) and frontal plane kinematic variables (TE 15 to 3°, ICC -0.11 to 0.88) ranged from ‘poor’ to ‘excellent’ for the individual movement tests (TE 0.7 to 1.5 pts, and 3 to 15°, ICC 0.14 to 0.87, and -0.11 to 0.88), but the within-session reliability of the sagittal plane flexion angles was ‘good’ to ‘excellent’ for all movement tests (TE 1 to 7°, ICC 0.60 to 0.97). The between-session reliability of rating scores (TE 0.8 to 0.5 pts, ICC 0.62 to 0.98) and kinematic variables (TE 8 to 1°, ICC 0.30 to 0.88) were predominantly ‘good’ to ‘excellent’ for all tests. No significant systematic changes were observed in rating score within- or between-sessions for any of the tests. CONCLUSIONS: These results suggest the TJFT could be clinically useful for monitoring lower limb function in adolescent athletes. The need for further investigation of movement variability associated with performance, scoring and interpretation of movement screening tests is also highlighted.en_NZ
dc.language.isoenen_NZ
dc.rightsAll rights reserveden_NZ
dc.subjectmale atheletesen_NZ
dc.subjectreliabilityen_NZ
dc.subjectbiological variabilityen_NZ
dc.subjectlower limben_NZ
dc.subjectmovement screeningen_NZ
dc.subjecttriple-joint flexion test (TJFT)en_NZ
dc.titleAn investigation of the biological variability of the Triple-Joint Flexion Test in adolescent male athletes using 2-D video analysisen_NZ
dc.typeMasters Thesisen_NZ
dc.rights.holderAuthoren_NZ
thesis.degree.nameMaster of Osteopathyen_NZ
thesis.degree.levelMastersen_NZ
thesis.degree.grantorUnitec Institute of Technologyen_NZ
dc.subject.marsden110499 Complementary and Alternative Medicine not elsewhere classifieden_NZ
dc.identifier.bibliographicCitationTaingahue, M.J. (2015). An investigation of the biological variability of the Triple-Joint Flexion Test in adolescent male athletes using 2-D video analysis. An unpublished thesis submitted in partial fulfilment of the requirements for the degree of Master of Osteopathy. Unitec Institute of Technology.en_NZ
unitec.pages64en_NZ
dc.contributor.affiliationUnitec Institute of Technologyen_NZ
unitec.advisor.principalMoran, Robert
unitec.institution.studyareaOsteopathy


Files in this item

Thumbnail

This item appears in

Show simple record


 Unitec Institute of Technology, Private Bag 92025, Victoria Street West, Auckland 1142